How to Measure Flow Rate

Flow RATE

In order to periodically confirm that a water project funded by Ingomar Living Waters is still in operation, we do audits of previously-funded projects.  We commission on-site and/or remote audits to collect updated information on an existing water project. Measuring the initial well flow allows us to confirm the success of the well installation. Later, we will measure the flow during the audit to determine how the flow has changed.

Measuring the flow rate in gallons or litres is straightforward.  You will need a jerry can to do the test and you need to know the exact capacity of the jerry can.  For example, the jerry can pictured below has a 20 litre capacity with a clearly-marked fill line at 20L.

To measure the well flow rate, place the jerry can under the wellhead, and start a stopwatch (could be on your smartphone) as you begin pumping at full rate.  Measure the time in seconds it takes to put exactly 20L of water in the jerry can.

Say it takes 11 seconds to fill to the 20L line pumping at full rate.  Then, the LPM, or litres per minute flow rate of that well is:

20 litres / 11 seconds

= 1.82 litres / second (20/11 = 1.82)

= 109.1 litres / minute (or 109.1 LPM)

If the calculation above is hard for you, then please just send us the time in seconds it took to fill your jerry can to the fill mark and let us know the EXACT capacity of your jerry can to the fill mark and we can calculate the LPM (litres per minute) or GPM (gallons per minute).